1. Which of the following is true for the multiple start screw threads?

Correct : C. it gives a quick transverse

2. Statement 1: Flank angle of symmetrical thread is known as thread’s half-angle. Statement 2: It is measured parallel to the axis of a thread.

Correct : A. t, f

3. Flanks of the threads connect the crest with the roots.

Correct : A. true

4. What is the effect of improper alignment of each tooth?

Correct : C. load will not distributed evenly

5. Which of the following is not true about concentricity of teeth?

Correct : D. should be tested to ensure the proper heat treatment

6. Which of the following option is true about an analytical method of inspection of gears?

Correct : C. all individual elements of gear teeth are checked

7. Which of the following element is not determined by analytical inspection?

Correct : B. composite vibrations

8. Statement 2: Gear blank should be tested for dimensional accuracy.

Correct : D. t, t

9. Which of the following is not determined by the functional type of inspection?

Correct : A. lead

10. Which of the following statement is true about inspection of gear?

Correct : B. backlash is determined by analytic inspection

11. Which of the following machine is used for rolling tests?

Correct : A. parkson gear tester

12. If reference circle of gear is eccentric then which error is reflected by this eccentricity?

Correct : C. pitch error

13. Statement 2: Accuracy of individual elements is necessary for precision gears.

Correct : D. f, t

14. best method for examining the surface finish. Visual, touch and scratch inspection methods are not as accurate as microscopic. In these methods, minute flaws can’t be detected.

Correct : C. 0.01 mm

15. Which of the following material is not used for rubbing on the surface to be inspected in scratch inspection?

Correct : B. hard material

16. Statement 2: Direct instrument measurement is enabled to determine a numerical value of surface finish.

Correct : A. f, t

17. What is the limitation of microscopic inspection to check surface finish?

Correct : B. small portion of surface can be detected at a time

18. In the method of microscopic inspection what is the angle of beam light with the work?

Correct : C. 600

19. Which of the following is true for a method of measurement of surface finish with surface photographs?

Correct : A. different type of illumination is needed

20. In case of vertical illumination in measuring surface finish with surface photographs, which will appear as bright area?

Correct : A. flat portion

21. Which of the following method use pendulum in measuring the surface finish?

Correct : B. wallace surface dynamometer

22. Which of the following is not true for the method of measurement of surface finish by micro interferometer?

Correct : C. depth of defect can’t be measured

23. Which of the following is the direct measure of surface finish in Wallace surface dynamometer?

Correct : A. time of swing

24. Which of the following is a destructive method in measuring surface finish?

Correct : B. taper sectioning

25. In which type of system does power transmission takes place through compressed air?

Correct : C. pneumatic system

26. The compressed air flows to the actuator through

Correct : A. pipes and valves

27. The compressed air is delivered to the pneumatic system through the air compressor.

Correct : A. true

28. What is the function of the air dryer?

Correct : B. removes moisture

29. Which part of the Pneumatic system stores the compressed air?

Correct : C. air receiver tank

30. Which type of pumps can give discharge even at high pressure?

Correct : C. rotary pumps

31. Which type of component in the hydraulic system supports less vibration and noise?

Correct : C. rotatory pumps

32. Hydraulic systems are slower in operation.

Correct : A. true

33. What prevents the leakage of oil inside an unbalanced vane pump?

Correct : A. vanes

34. Which among the following are not the main selection criteria for selection of hydraulic pumps?

Correct : D. weight

35. Which is the cheapest device for measuring flow / discharge rate.

Correct : C. orificemeter

36. The principle of Orificemeter is same as that of Venturimeter.

Correct : A. true

37. The Orificemeter readings are more accurate than Venturimeter.

Correct : B. false

38. The Orificemeter readings are more accurate than Pitot tube readings.

Correct : B. false

39. The Orificemeter has a smooth edge hole.

Correct : B. false

40. A nanometre is connected to a section which is at a distance of about 4 to 6 times the pipe diameter upstream from orifice plate.

Correct : B. false

41. Venturimeter is based on integral form of Euler’s equation.

Correct : A. true

42. Orifice Meter can only be used for measuring rate of flow in open pipe like structure.

Correct : A. true

43. Orifice meter consists of a flat rectangular plate.

Correct : B. false

44. TOPIC 5.3 TEMPERATURE: BIMETALLIC STRIP, THERMOCOUPLES

Correct : C. displacement

45. Which of the following can be used for measuring temperature?

Correct : B. fluid expansion system

46. IPTS stands for

Correct : A. international practical temperature scale

47. In liquid in steel bulb thermometer, which liquid can be used for measuring temperature up to 60000C?

Correct : A. mercury

48. Which of the following is used as indication instrument in a liquid expansion system?

Correct : B. bourdon tube

49. Which of the following is true for bimetallic type thermometer?

Correct : B. two metals have different temperature coefficient

50. When bimetallic thermometer heated, curling occurs to the side of metal with least temperature coefficients.

Correct : A. true

51. Analogous quantities of heat flow and temperature in electrical are                             and

Correct : B. current and potential

52. Ratio of net amount of heat received and stored in the body for certain time interval is known as

Correct : C. thermal storage capacity

53. Heat transfer coefficient of a material with length l is

Correct : A. k/l

54. Resistance temperature detector is

Correct : A. a electrical transducer

55. Sensing element in the thermometer must provide

Correct : C. large change in resistance

56. Resistance thermometer provides the change in electrical resistance.

Correct : A. true

57. If the sensing element is large, then less amount of heat is required.

Correct : B. false

58. In a temperature sensing element

Correct : D. high value of α is required

59. Nickel and its alloys can be used over a temperature range of

Correct : A. 100 to 450 k

60. How can corrosion be prevented in a resistance thermometer?

Correct : B. by enclosing the elements in a glass tube

61. What is the maximum permissible error for class I micrometers?

Correct : B. 0.004 mm

62. Which of the following is caused by careless handling?

Correct : B. gross error

63. ‘A system will be error free if we remove all systematic error’.

Correct : B. false

64. Which of the following is not a fundamental quantity?

Correct : B. angle

65. Which standard is fixed and used for industrial laboratories?

Correct : C. secondary standard

66. Which of the following error is caused by poor calibration of the instrument?

Correct : C. systematic error

67. How systematic errors are eliminated?

Correct : B. replacement of instrument

68. Starting position of an object is represented as x=5.1±0.2m and finishing position as y=6.9±0.3m. What will be the displacement and error in displacement?

Correct : C. displacement = 1.8m, error = 0.36m

69. Which of the following is correct for selective assembly?

Correct : D. this method is followed in ball and roller bearing units

70. For checking straightness, straight edge is placed over a surface and these two are viewed against the light. Which of the following option true if colour of light is red?

Correct : D. gap between 0.0012 to 0.0017 mm

71. Which of the following is the best for the examination of surface finish?

Correct : D. microscopic inspection

72. What is the relationship between Orificemeter diameter and pipe diameter

Correct : C. orificemeter diameter is one fourth times the pipe diameter

73. 3 TEMPERATURE: BIMETALLIC STRIP, THERMOCOUPLES

Correct : C. displacement

74. Relation between temperature and resistance of a conductor is

Correct : B. rt = rref [1+α∆t]

75. Most metallic conductors have a