Quiznetik

Building Services | Set 2

1. Water proofing treatment is one type of

Correct : D. Multiple services

2. Aims of good lighting

Correct : D. all of above

3. Principles of lighting

Correct : D. all of above

4. The value of Illumination in lux of Residential building

Correct : A. 100-150-200

5. The value of Illumination in lux of Schools

Correct : B. 200-300

6. The value of Illumination in lux of stairs

Correct : A. 100-150-200

7. The value of Illumination in lux of Reading room

Correct : C. 300

8. The value of Illumination in lux of Industrial building

Correct : D. 100-450

9. The value of Illumination in lux of Airport building

Correct : C. 300

10. Due to light sources within the field of vision is called_________

Correct : A. Direct glare

11. Due to reflection from light sources or surfaces of excessive brightness is called_________

Correct : B. Reflected glare

12. where the peripheral field is comparatively very bright is called_________

Correct : C. Veiling Glare

13. Excessive contrast or abrupt and large changes in brightness produces the effect of ______

Correct : D. Glare

14. Total quantity of light emitted from a point source of light per second is called____________

Correct : A. luminous flux

15. It is the SI unit of luminous is called____________

Correct : D. Lumen

16. Amount of luminous flux emitted from a source in any one direction per unit solid angle is called____________

Correct : B. luminous intensity

17. the SI unit of luminous intensity is called____________

Correct : C. candela

18. The ease and certainty with which an eye can seen an object is called____________

Correct : B. visual task

19. The light received by the earth from the sun consists how many parts?

Correct : B. 2

20. The relative amount of sky illuminance depends on

Correct : D. all of the above

21. For Indian conditions, how much solar altitude is assumed as the standard for design purposes.

Correct : B. 12

22. The recommended design sky illuminance values for cold climate is

Correct : A. 6800

23. The recommended design sky illuminance values for warm humid climate is

Correct : C. 9000

24. The recommended design sky illuminance values for hot dry climate is

Correct : D. 10500

25. The recommended design sky illuminance values for composite climate is

Correct : B. 8000

26. The recommended design sky illuminance values for temperature climate is

Correct : C. 9000

27. The percentage of that part of daylight illumination at a point in the interior on a given plane which is received directly from the sky s called____________

Correct : B. sky component

28. The ratio (or percentage) of that part of the day light illuminance at a point on a given plane which is received by direct reflection from external surfaces is called____________

Correct : C. external reflected component

29. The ratio (or percentage) of that part of the daylight illuminance at a point in a given plane which is received by direct reflection or inter-reflection from the internal surfaces is called____________

Correct : A. internal reflected component

30. In which case artificial lighting is necessary?

Correct : D. all of the above

31. Which one is not a type of metal filament lamp?

Correct : D. b & c

32. Which is the type of incandescent lamp?

Correct : A. Carbon filament lam

33. Necessity of ventilation is ____________

Correct : D. all of the above

34. Necessity of ventilation is ____________

Correct : D. all of the above

35. Requirement of ventilation is ____________

Correct : D. all of the above

36. The minimum & maximum rate of air change is 60 per hour.

Correct : C. 1, 60

37. As per IS : 3362-1965 recommends the following air changes in residential buildings for living room is

Correct : A. minimum 3

38. As per IS : 3362-1965 recommends the following air changes in residential buildings for bathroom is

Correct : C. minimum 6

39. As per IS : 3362-1965 recommends the following air changes in residential buildings for passage is

Correct : D. no need

40. As per IS : 3362-1965 recommends the following air changes in residential buildings for kitchen is

Correct : A. minimum 3

41. Requirement of air changes per hour in an enclosed area as per NBC 2005 for assembly hall

Correct : B. 4-8

42. Requirement of air changes per hour in an enclosed area as per NBC 2005 for bed rooms

Correct : A. 2-4

43. Requirement of air changes per hour in an enclosed area as per NBC 2005 for conference room

Correct : C. 8-12

44. Requirement of air changes per hour in an enclosed area as per NBC 2005 for cinema

Correct : D. 10-15

45. Requirement of air changes per hour in an enclosed area as per NBC 2005 for hospital

Correct : B. 6-8

46. Requirement of air changes per hour in an enclosed area as per NBC 2005 for libraries

Correct : A. 3-5

47. Requirement of air changes per hour in an enclosed area as per NBC 2005 for factories

Correct : D. 8-10