4. The value of Illumination in lux of Residential building
Correct : A. 100-150-200
5. The value of Illumination in lux of Schools
Correct : B. 200-300
6. The value of Illumination in lux of stairs
Correct : A. 100-150-200
7. The value of Illumination in lux of Reading room
Correct : C. 300
8. The value of Illumination in lux of Industrial building
Correct : D. 100-450
9. The value of Illumination in lux of Airport building
Correct : C. 300
10. Due to light sources within the field of vision is called_________
Correct : A. Direct glare
11. Due to reflection from light sources or surfaces of excessive brightness is called_________
Correct : B. Reflected glare
12. where the peripheral field is comparatively very bright is called_________
Correct : C. Veiling Glare
13. Excessive contrast or abrupt and large changes in brightness produces the effect of ______
Correct : D. Glare
14. Total quantity of light emitted from a point source of light per second is called____________
Correct : A. luminous flux
15. It is the SI unit of luminous is called____________
Correct : D. Lumen
16. Amount of luminous flux emitted from a source in any one direction per unit solid angle is
called____________
Correct : B. luminous intensity
17. the SI unit of luminous intensity is called____________
Correct : C. candela
18. The ease and certainty with which an eye can seen an object is called____________
Correct : B. visual task
19. The light received by the earth from the sun consists how many parts?
Correct : B. 2
20. The relative amount of sky illuminance depends on
Correct : D. all of the above
21. For Indian conditions, how much solar altitude is assumed as the standard for design
purposes.
Correct : B. 12
22. The recommended design sky illuminance values for cold climate is
Correct : A. 6800
23. The recommended design sky illuminance values for warm humid climate is
Correct : C. 9000
24. The recommended design sky illuminance values for hot dry climate is
Correct : D. 10500
25. The recommended design sky illuminance values for composite climate is
Correct : B. 8000
26. The recommended design sky illuminance values for temperature climate is
Correct : C. 9000
27. The percentage of that part of daylight illumination at a point in the interior on a given plane
which is received directly from the sky s called____________
Correct : B. sky component
28. The ratio (or percentage) of that part of the day light illuminance at a point on a given plane which is received by direct reflection from external surfaces is called____________
Correct : C. external reflected component
29. The ratio (or percentage) of that part of the daylight illuminance at a point in a given plane which is received by direct reflection or inter-reflection from the internal surfaces is called____________
Correct : A. internal reflected component
30. In which case artificial lighting is necessary?
Correct : D. all of the above
31. Which one is not a type of metal filament lamp?
Correct : D. b & c
32. Which is the type of incandescent lamp?
Correct : A. Carbon filament lam
33. Necessity of ventilation is ____________
Correct : D. all of the above
34. Necessity of ventilation is ____________
Correct : D. all of the above
35. Requirement of ventilation is ____________
Correct : D. all of the above
36. The minimum & maximum rate of air change is 60 per hour.
Correct : C. 1, 60
37. As per IS : 3362-1965 recommends the following air changes in residential buildings for living
room is
Correct : A. minimum 3
38. As per IS : 3362-1965 recommends the following air changes in residential buildings for
bathroom is
Correct : C. minimum 6
39. As per IS : 3362-1965 recommends the following air changes in residential buildings for
passage is
Correct : D. no need
40. As per IS : 3362-1965 recommends the following air changes in residential buildings for
kitchen is
Correct : A. minimum 3
41. Requirement of air changes per hour in an enclosed area as per NBC 2005 for assembly hall
Correct : B. 4-8
42. Requirement of air changes per hour in an enclosed area as per NBC 2005 for bed rooms
Correct : A. 2-4
43. Requirement of air changes per hour in an enclosed area as per NBC 2005 for conference
room
Correct : C. 8-12
44. Requirement of air changes per hour in an enclosed area as per NBC 2005 for cinema
Correct : D. 10-15
45. Requirement of air changes per hour in an enclosed area as per NBC 2005 for hospital
Correct : B. 6-8
46. Requirement of air changes per hour in an enclosed area as per NBC 2005 for libraries
Correct : A. 3-5
47. Requirement of air changes per hour in an enclosed area as per NBC 2005 for factories